| CERTIFICATION |
CENELEC
SIRA00ATEX1094 I M2 II 2DG E Ex de IandIIC
SIRA00ATEX1094 II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IIC
POCC GB MΠ14.B00030
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U |
 |
INGRESS
PROTECTION |
IP66 68, CSA Enclosure Type (NEMA) 4X 6P
|
| IMPACT RESISTANCE |
20Nm (7Nm Aluminium) |
| OPERATING
TEMPERATURES |
Nitrile ‘O’ Ring -30ºC to +100ºC
Silicone ‘O’ Ring -50ºC to +180ºC |
| MATERIALS |
Brass CZ121 (SPMH)
316 Stainless Steel (SPMHS)
Aluminium Alloy (SPMHA) |
|
| THREADS |
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG |
| SEALS |
The standard ‘O’ Ring material is Nitrile |
| PLATING |
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) |
| EXAMPLE PART
NUMBER |
Sample: SPMH/NP/M20
SPMH - Stopping Plug type and body material (Brass)
NP - Nickel plating
M20 - Male thread size |
| SIZES AVAILABLE AND DIMENSIONAL REFERENCES |
| Metric |
Dim Ref |
NPT |
Dim Ref |
ISO Pipe |
Dim Ref |
PG |
Dim Ref |
|
| M16 |
B |
|
|
|
|
7 |
A |
| M20 |
C |
1/2" |
D |
1/2" |
D |
9 |
B |
| M25 |
C |
3/4" |
D |
3/4" |
D |
11 |
C |
| M32 |
C |
1” |
F |
1” |
D |
13.5 |
C |
| M40 |
C |
1*1/4" |
F |
1*1/4" |
D |
16 |
C |
| M50 |
C |
1*1/2" |
F |
1*1/2" |
D |
21 |
C |
| M63 |
C |
2” |
F |
2” |
D |
29 |
C |
| M75 |
C |
2*1/2" |
G |
2*1/2" |
D |
36 |
C |
| M80 x 2.0 |
E |
3” |
G |
3” |
D |
42 |
C |
| M85 x 2.0 |
E |
3*1/2" |
G |
|
|
48 |
C |
| M90 x 2.0 |
E |
4” |
G |
|
|
|
|
| M100 x 2.0 |
E |
|
|
|
|
|
|
|
| DIMENSIONS |
| Dimension Reference |
A |
B |
C |
D |
E |
F |
G |
|
| Head Diameter |
Minimum 6.0mm larger than the major thread diameter |
| Hex Socket
A/F |
6.0 |
8.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
| Total Length |
21.5 |
21.5 |
21.5 |
24.5 |
25.5 |
29.0 |
39.0 |
| Thread Length |
16.0 |
16.0 |
16.0 |
19.0 |
22.0 |
23.5 |
33.5 |
|
| All Dimensions are in Millimetres |
NOTES:
- SPMH type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded entries
we would recommend the use of SPA type stopping plugs
- Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in
full
- Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
- For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)
- For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads
- Where metallic stopping plugs are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system
- When ordering one needs to specify if IECEx or ATEX certification is required. ATEX versions are supplied as standard.
|