| CERTIFICATION |
CENELEC
SIRA00ATEX1094 (Metric Female)
SIRA99ATEX1115U (Non-Metric Female)
I M2 II 2DG E Ex de IandIIC
II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IICU
POCC GB MΠ14.B00030
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U |
 |
INGRESS
PROTECTION |
IP66 68, CSA Enclosure Type (NEMA) 4X 6P
|
| IMPACT RESISTANCE |
20Nm (7Nm Aluminium) |
| OPERATING
TEMPERATURES |
Nitrile ‘O’ Ring -30ºC to +100ºC
Silicone ‘O’ Ring -50ºC to +180ºC |
| MATERIALS |
Brass CZ121 (ARB)
316 Stainless Steel (ARS)
Aluminium Alloy (ARA) |
|
| THREADS |
ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG |
| SEALS |
The standard ‘O’ Ring material is Nitrile
Tapered male thread options are not normally supplied c/w ‘O’ ring seal, thread sealant should be used to
maintain the desired level of ingress protection |
| PLATING |
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) |
| EXAMPLE PART
NUMBER |
Sample: ARB/NP/M20/050NPT
AR - Adapter/Reducer type
B - Body material (Brass)
NP - Nickel plating
M20 - Male thread size
050NPT - Female thread size (1.2h NPT) |
| GAVAILABLE THREAD SIZES AND CORRESPONDING BORE SIZE |
| Metric |
Bore |
NPT |
Bore |
ISO Pipe |
Bore |
ET |
Bore |
PG |
Bore |
|
| M16 |
10.0 |
|
|
|
|
|
|
7 |
8.0 |
| M20 |
14.0 |
1/2" |
15.0 |
1/2" |
15.0 |
3.4" |
14.0 |
9 |
10.0 |
| M25 |
18.0 |
3/4" |
19.0 |
3/4" |
19.0 |
1” |
18.0 |
11 |
13.5 |
| M32 |
24.0 |
1” |
25.0 |
1” |
25.0 |
1*1/4" |
24.0 |
13.5 |
14.0 |
| M40 |
32.0 |
1*1/4" |
32.0 |
1*1/4" |
32.0 |
1*1/2" |
32.0 |
16 |
16.0 |
| M50 |
41.0 |
1*1/2" |
38.0 |
1*1/2" |
38.0 |
2” |
41.0 |
21 |
21.0 |
| M63 |
53.0 |
2” |
49.0 |
2” |
49.0 |
2*1/2" |
53.0 |
29 |
29.0 |
| M75 |
64.0 |
2*1/2" |
60.0 |
2*1/2" |
60.0 |
3” |
64.0 |
36 |
38.0 |
| M80 x 2.0 |
69.0 |
3” |
75.0 |
3” |
75.0 |
|
|
42 |
45.0 |
| M85 x 2.0 |
73.0 |
3*1/2" |
88.0 |
3*1/2" |
88.0 |
|
|
48 |
50.0 |
| M90 x 2.0 |
78.0 |
4” |
100.0 |
4” |
100.0 |
|
|
|
|
| M100 x 2.0 |
88.0 |
|
|
|
|
|
|
|
|
|
| All Dimensions are in Millimetres |
NOTES:
- Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and
adhered to in full
- Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
- For Flameproof Exd applications the female thread into which the adaptor or reducer is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1)
- For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads
- Where AR adaptors and reducers are fitted into non-metallic Increased Safety Exe enclosures they must be included within the
earth circuit of the system
- 316 Stainless Steel versions do not feature a marking band. This reduces the overall length of reducers by 5mm, it does not affect
the overall length of Adaptors/li>
- Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the
entry thread of the enclosure
- Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread
- When ordering one needs to specify if IECEx or ATEX certification is required. ATEX versions are supplied as standard.
|